Sprinkler Reducer Welded (KP)

Sprinkler Reducer Welded (KP)
Sprinkler Reducer Welded (KP)

Sprinkler Reducer Welded (KP) Specification

  • Coating Type
  • Fire Red Epoxy Powder
  • Tensile Strength
  • 410 MPa
  • Yield Strength
  • 250 MPa
  • Sealing Type
  • Welded Joint (no seal required)
  • Tolerance
  • 0.1 mm
  • Temperature Range
  • -10C to 110C
  • Diameter
  • 1 x 1/2, 2 x 1-1/2, etc.
  • Connection Type
  • Butt Weld
  • Bend Radius
  • Formed as per Standard
  • Flexibility
  • Rigid
  • Product Type
  • Sprinkler Reducer Welded (KP)
  • Material
  • Mild Steel
  • Connection
  • Welded
  • Shape
  • Reducer (Concentric)
  • Standard
  • ASTM A234 / IS 1239
  • Surface Treatment
  • Red Painted
  • Outer Diameter
  • 33.7 mm 60.3 mm
  • Section Shape
  • Round
  • Length
  • 60 mm 120 mm
  • Thickness
  • 2.6 mm 3.0 mm
  • Color
  • Red
  • Usage
  • Fire Sprinkler System
  • Rated Pressure
  • 16 bar
  • Material Grade
  • KP (Fire Protection Grade)
  • Application
  • Fire Fighting Plumbing
  • Installation Method
  • Butt-Welded to Piping
  • Packing Type
  • Gunny Bag or Carton
  • End Type
  • Plain End (for Welding)
  • Compatible Pipe Material
  • Carbon Steel / Mild Steel Fire Pipe
  • Lead Content
  • Lead-Free (as per IS 1239)
  • Pressure Class
  • PN16
  • Corrosion Resistance
  • High (suitable for fire line use)
  • Fire Resistance
  • Compliant with Fire System Requirements
  • Inspection
  • 100% Visual & Dimensional
  • Weight
  • Variable as per size (approx. 0.20.8 kg)
 
 

About Sprinkler Reducer Welded (KP)

Providing you the best range of Agricultural HDPE Pipe Fittings  i.e. Adapter, EP Reducer Welded, Pipe Coupler, Tail Socket, Pipe Black Coupler and KP End Cap with effective & timely delivery

Exceptional Fire & Corrosion Resistance

Engineered for fire protection, this sprinkler reducer complies with stringent fire system requirements and exhibits superior corrosion resistance. Its mild steel construction with a red epoxy coating ensures durability in demanding environments, while lead-free manufacturing meets IS 1239 standards for safety. Designed for both longevity and performance, it offers a dependable solution for fire-fighting plumbing.


Flexible Sizing for Precise Fitment

Sizes range from 33.7 mm to 60.3 mm in outer diameter and 60 mm to 120 mm in length, with thicknesses of 2.6-3.0 mm. This flexibility supports various sprinkler line configurations. The reducer is shaped concentrically for even flow, guaranteeing seamless integration into fire systems and supporting a pressure class of PN16 for robust operation.


Installation Process and Quality Assurance

Installation is straightforward via butt welding to compatible carbon or mild steel fire pipes. Rigid design ensures a secure, leak-free weld joint without the need for additional seals. Every product undergoes 100% visual and dimensional inspection with meticulous tolerances (0.1 mm), ensuring top-tier quality for safe fire system operation.

FAQ's of Sprinkler Reducer Welded (KP):


Q: How is the Sprinkler Reducer Welded (KP) installed in fire sprinkler systems?

A: The reducer is butt-welded to carbon steel or mild steel fire pipes with plain ends, creating a robust, leak-free connection without the need for additional sealing components.

Q: What makes this reducer suitable for fire fighting applications?

A: It is constructed from KP-grade mild steel, adheres to ASTM A234 and IS 1239 standards, and features high fire resistance and a fire red epoxy coating to ensure safety and compliance in fire sprinkler systems.

Q: When should I use this reducer in my fire protection system?

A: Use this reducer when you need to transition between pipe sizes within fire sprinkler or firefighting plumbing systems, ensuring compliant, secure connections that withstand high pressure and temperature variations.

Q: Where can I source this Sprinkler Reducer Welded (KP) in India?

A: You can purchase this fitting from authorized manufacturers, producers, retailers, suppliers, traders, or wholesalers specializing in fire protection equipment across India.

Q: What are the benefits of using a welded sprinkler reducer with high corrosion resistance?

A: The welded joint ensures rigidity and leak-free performance, while high corrosion resistance increases service life, and the fire-resistant coating provides added safety in harsh conditions.

Q: What is the process for quality assurance prior to shipping?

A: Every reducer undergoes 100% visual and dimensional inspection with strict tolerances (0.1 mm) to guarantee compliance with standards and reliable field performance.

Q: Is this reducer environmentally safe for potable water or lead-sensitive applications?

A: Yes, the product is manufactured lead-free as per IS 1239, making it safe for environments sensitive to lead contamination.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Pipes Fittings Category

Sprinkler Reducing Group Coupler ( EP )

Sprinkler Reducing Group Coupler ( EP )

Price 80 INR / Piece

Minimum Order Quantity : 10 Pieces

Color : Red

Shape : Round

Length : Variable (depending on size)

Section Shape : Other, Cylindrical

Sprinkler  Group Reducing Nipple

Sprinkler Group Reducing Nipple

Price 15 INR / Piece

Minimum Order Quantity : 10 Pieces

Color : Golden

Shape : Other, Hexagonal

Length : 35 mm

Section Shape : Round

Sprinkler Both side group nipple

Sprinkler Both side group nipple

Price 30 INR / Piece

Minimum Order Quantity : 10 Pieces

Color : Silver

Shape : Round

Length : 100 mm

Section Shape : Other, Cylindrical

Sprinkler End Cap ( KP )

Sprinkler End Cap ( KP )

Price 10 INR / Piece

Minimum Order Quantity : 10 Pieces

Color : Silver

Shape : Round

Length : 35 mm

Section Shape : Other, Circular



Back to top